House design · Detail the envelope · design-17Control vapour and manage moisture
Warm moist indoor air condensing inside walls causes rot and mould. The fix depends on climate and wall type, so copy a detail proven in your climate.
How
- Know the classes (US IRC): Class I is 0.1 perm or less. Class II is above 0.1 and up to 1.0 perm. Class III is above 1.0 and up to 10 perm.
- The IRC requires a Class I or II vapour retarder on the interior side of frame walls in climate zones 5, 6, 7, 8 and Marine 4. Mild and hot climates generally do not need one (DOE).
- IRC exceptions include basement walls, the below-grade part of any wall, and walls of materials not damaged by moisture or freezing. A responsive vapour retarder is allowed inside in any zone.
- Do not trap moisture: avoid two impermeable layers on both sides of a wall.
- Natural walls must breathe: the US straw bale appendix bans Class I and II retarders on bale walls and Your Home advises against cement render on straw.
- Shed rain first: overhangs, flashings, drip edges, a drained cavity behind cladding where needed (NZ) and ground clearance.
- Manage indoor moisture with kitchen and bathroom extraction (thermal module).