Specify ember-resistant construction

Most homes lost in wildfires are ignited by wind-blown embers and small nearby fires, not by a wall of flame. Simple details on the roof, vents, gutters, decks and fences close the gaps embers use.

How

  1. Roof: choose noncombustible or Class A rated roofing (a US rating) and seal open ends of tile profiles and ridge gaps, as FEMA advises.
  2. Vents: cover attic, eave and crawl space vents with metal mesh of 1/8 inch (about 3 mm) or smaller. FEMA notes 1/16 inch mesh also works but clogs faster.
  3. Gutters: use metal gutters and noncombustible gutter guards, and keep them clear.
  4. Walls: FEMA suggests noncombustible siding on the lowest 2 to 3 courses, and sealing gaps between siding and foundation.
  5. Windows and doors: seal gaps around frames with fire-resistant sealant and use fire-rated weather stripping.
  6. Decks: use ignition-resistant decking, keep the board strip within 1 ft (30 cm) of the wall noncombustible, and enclose the space under decks.
  7. Fences: FEMA recommends noncombustible fencing for at least the first 5 ft (1.5 m) where a fence joins the house.
  8. Pass these details to the design module so they are in the drawings, not added later.
  9. For construction ratings by exposure level, including the Australian bushfire attack levels, see design-28.

Do these first